IDIAG Operate v1

The IDIAG Operate connected solution optimizes asset management, it alerts when an asset fails or encounters a critical malfunction.

Details:

  • device: IDIAG_Operate
  • version: 1
  • deviceType: IDIAG_Operate_v1

Message: Asset Critical

Occurrence: When the asset goes into critical state

eventId: asset-critical

Resources:

Critical state

True if the equipment is in critical state.
False otherwise.

Details:

  • name: critical-state
  • category: state
  • unit: unit.nounit
  • type: bool

Current

The last measured current.

Details:

  • name: current
  • category: current
  • unit: unit.ampere.rms
  • type: number
  • min value: 0
  • max value: 100
  • error value: 163.83

Message: Asset Start

Occurrence: When the asset state goes from stopped to started

eventId: asset-start

Resources:

State

The current state of the equipment :

  • 0: Stopped
  • 1: Started
  • 2: Unknown

Details:

  • name: state
  • category: state
  • unit: unit.nounit
  • type: number
  • min value: 0
  • max value: 2

Current

The last measured current.

Details:

  • name: current
  • category: current
  • unit: unit.ampere.rms
  • type: number
  • min value: 0
  • max value: 100
  • error value: 163.83

Message: Asset Stop

Occurrence: When the asset state goes from started to stopped

eventId: asset-stop

Resources:

State

The current state of the equipment :

  • 0: Stopped
  • 1: Started
  • 2: Unknown

Details:

  • name: state
  • category: state
  • unit: unit.nounit
  • type: number
  • min value: 0
  • max value: 2

Current

The last measured current.

Details:

  • name: current
  • category: current
  • unit: unit.ampere.rms
  • type: number
  • min value: 0
  • max value: 100
  • error value: 163.83

Message: Keep Alive

Occurrence: Every 24 hours

eventId: keep-alive

Resources:

State

The current state of the equipment :

  • 0: Stopped
  • 1: Started
  • 2: Unknown

Details:

  • name: state
  • category: state
  • unit: unit.nounit
  • type: number
  • min value: 0
  • max value: 2

Critical state

True if the equipment is in critical state.
False otherwise.

Details:

  • name: critical-state
  • category: state
  • unit: unit.nounit
  • type: bool

Current

The last measured current.

Details:

  • name: current
  • category: current
  • unit: unit.ampere.rms
  • type: number
  • min value: 0
  • max value: 100
  • error value: 163.83

Is main supply

True if the device is using the main power supply.
False if the device is using the battery.

Details:

  • name: is-main-supply
  • category: condition
  • unit: unit.nounit
  • type: bool

Power supply voltage

The power supply voltage.

Details:

  • name: power-supply-voltage
  • category: voltage
  • unit: unit.volt
  • type: number
  • min value: 0
  • max value: 3.7
  • error value: 4.095

Connectivity

Coming up later.

Details:

  • name: connectivity
  • category: condition
  • unit: unit.nounit
  • type: bool

Message: Starting

Occurrence: When sensor device starts

eventId: device-start

Resources:

State

The current state of the equipment :

  • 0: Stopped
  • 1: Started
  • 2: Unknown

Details:

  • name: state
  • category: state
  • unit: unit.nounit
  • type: number
  • min value: 0
  • max value: 2

Critical state

True if the equipment is in critical state.
False otherwise.

Details:

  • name: critical-state
  • category: state
  • unit: unit.nounit
  • type: bool

Current

The last measured current.

Details:

  • name: current
  • category: current
  • unit: unit.ampere.rms
  • type: number
  • min value: 0
  • max value: 100
  • error value: 163.83