SENSE Surface Rail Temperature v3

Temperature sensor for train tracks.

Details:

  • device: SENSE_Surface_Rail_Temperature
  • version: 3
  • deviceType: SENSE_Surface_Rail_Temperature_v3

Message: Periodic measurement

Occurrence: 20 minutes

Sends an average of the temperature (measured every minute) since the last message.

eventId: data

Resources:

Internal min

Minimum sensor's internal temperature since last message.

Details:

  • name: internal_min
  • category: temperature
  • unit: unit.celsius
  • type: number
  • min value: -40
  • max value: 85
  • error value: 86

Internal max

Maximum sensor's internal temperature since last message.

Details:

  • name: internal_max
  • category: temperature
  • unit: unit.celsius
  • type: number
  • min value: -40
  • max value: 85
  • error value: 86

Internal avg

Average sensor's internal temperature since last message.

Details:

  • name: internal_avg
  • category: temperature
  • unit: unit.celsius
  • type: number
  • min value: -40
  • max value: 85
  • error value: 86

Track min

Minimum track temperature measured since last message.

Details:

  • name: track_min
  • category: temperature
  • unit: unit.celsius
  • type: number
  • min value: -40
  • max value: 150
  • error value: 160

Track max

Maximum track temperature measured since last message.

Details:

  • name: track_max
  • category: temperature
  • unit: unit.celsius
  • type: number
  • min value: -40
  • max value: 150
  • error value: 160

Track avg

Average track temperature measured since last message.

Details:

  • name: track_avg
  • category: temperature
  • unit: unit.celsius
  • type: number
  • min value: -40
  • max value: 150
  • error value: 160

Battery state

The current state of the device battery :

  • 0: Critical
  • 1: Low
  • 2: OK

Details:

  • name: battery_state
  • category: state
  • unit: unit.nounit
  • type: number
  • min value: 0
  • max value: 2
  • error value: 3

Message: Startup

Occurrence: Message sent when device starts for the first time or reboots

eventId: startup

Resources:

Temperature internal

The device internal temperature.

Details:

  • name: temperature_internal
  • category: temperature
  • unit: unit.celsius
  • type: number
  • min value: -40
  • max value: 85
  • error value: 86

Temperature track

Instantaneous temperature on sensor startup.

Details:

  • name: temperature_track
  • category: temperature
  • unit: unit.celsius
  • type: number
  • min value: -40
  • max value: 150
  • error value: 160

Battery state

The current state of the device battery :

  • 0: Critical
  • 1: Low
  • 2: OK

Details:

  • name: battery_state
  • category: state
  • unit: unit.nounit
  • type: number
  • min value: 0
  • max value: 2
  • error value: 3