START GeolocTemp v2

Coupons connect├ęs / Geoloc Temp V2

Details:

  • device: START_GeolocTemp
  • version: 2
  • deviceType: START_GeolocTemp_v2

Message: movement

Occurrence: event based, when device is detected to be moving

eventId: movement

Resources:

Movement counter

number of detected movements

Details:

  • name: movement_counter
  • category: counter
  • unit: unit.nounit
  • type: number
  • min value: 0

Battery voltage

device battery voltage

Details:

  • name: battery_voltage
  • category: voltage
  • unit: unit.voltage
  • type: number
  • min value: 0
  • max value: 6.1
  • error value: 6.2

Movement detected

true if the device is moving

false if the device is not moving

Details:

  • name: movement_detected
  • category: condition
  • unit: unit.nounit
  • type: bool

Message: position

Occurrence: every 24h or 5mn after movement stopped

eventId: position

Resources:

Latitude

WGS84 latitude

Details:

  • name: latitude
  • category: position
  • unit: unit.deg
  • type: number
  • min value: 90
  • max value: -90
  • error value: 100

Longitude

WGS84 longitude

Details:

  • name: longitude
  • category: position
  • unit: unit.deg
  • type: number
  • min value: 180
  • max value: -180
  • error value: 200

Temperature internal

device internal temperature

Details:

  • name: temperature_internal
  • category: temperature
  • unit: unit.celsius
  • type: number
  • min value: -40
  • max value: 85
  • error value: 86

Temperature

measured temperature on track sensor

Details:

  • name: temperature
  • category: temperature
  • unit: unit.celsius
  • type: number
  • min value: -40
  • max value: 150
  • error value: 160

Movement detected

true if the device is moving

false if the device is not moving

Details:

  • name: movement_detected
  • category: condition
  • unit: unit.nounit
  • type: bool

Gps fix present

GPS signal acquisition

true if the last gps location measure succeeded

false if a gps signal could not be acquired on last attempt

Details:

  • name: gps_fix_present
  • category: condition
  • unit: unit.nounit
  • type: bool

Message: startup message

Occurrence: when devices starts for the first time or reboots

eventId: startup

Resources:

Temperature internal

device internal temperature

Details:

  • name: temperature_internal
  • category: temperature
  • unit: unit.celsius
  • type: number
  • min value: -40
  • max value: 85
  • error value: 86

Temperature

measured temperature on track sensor

Details:

  • name: temperature
  • category: temperature
  • unit: unit.celsius
  • type: number
  • min value: -40
  • max value: 150
  • error value: 160

Message: temperature measure

Occurrence: every 20mn

temperatures are measured every minute and the device derives the average (since the last message, or 20mn) and maximum/minimum measures.

eventId: temperature_measure

Resources:

Temperature internal min

minimum device temperature since the last message

Details:

  • name: temperature_internal_min
  • category: temperature
  • unit: unit.celsius
  • type: number
  • min value: -40
  • max value: 85
  • error value: 86

Temperature internal max

maximum device temperature since the last message

Details:

  • name: temperature_internal_max
  • category: temperature
  • unit: unit.celsius
  • type: number
  • min value: -40
  • max value: 85
  • error value: 86

Temperature internal avg

average device temperature since the last message

Details:

  • name: temperature_internal_avg
  • category: temperature
  • unit: unit.celsius
  • type: number
  • min value: -40
  • max value: 85
  • error value: 86

Temperature min

minimum track temperature since last message

Details:

  • name: temperature_min
  • category: temperature
  • unit: unit.celsius
  • type: number
  • min value: -40
  • max value: 150
  • error value: 160

Temperature max

maximum track temperature since last message

Details:

  • name: temperature_max
  • category: temperature
  • unit: unit.celsius
  • type: number
  • min value: -40
  • max value: 150
  • error value: 160

Temperature avg

average track temperature since last message

Details:

  • name: temperature_avg
  • category: temperature
  • unit: unit.celsius
  • type: number
  • min value: -40
  • max value: 150
  • error value: 160

Battery voltage

device battery voltage

Details:

  • name: battery_voltage
  • category: voltage
  • unit: unit.voltage
  • type: number
  • min value: 0
  • max value: 6.1
  • error value: 6.2

Message counter

counter for the number of sent messages

Details:

  • name: message_counter
  • category: counter
  • unit: unit.nounit
  • type: number
  • min value: 0

Display counter

counts the number of display activations (by tilting the device when installed on the track section)

Details:

  • name: display_counter
  • category: counter
  • unit: unit.nounit
  • type: number
  • min value: 0
  • error value: 1022

Movement detected

true if the device is moving

false if the device is not moving

Details:

  • name: movement_detected
  • category: condition
  • unit: unit.nounit
  • type: bool

Gps fix present

GPS signal acquisition

true if the last gps location measure succeeded

false if a gps signal could not be acquired on last attempt

Details:

  • name: gps_fix_present
  • category: condition
  • unit: unit.nounit
  • type: bool