START HumiTemp v1

Measure humidity and temperature

Details:

  • device: START_HumiTemp
  • version: 1
  • deviceType: START_HumiTemp_v1

Message: Data

Occurrence: every 1 hour

Sends statistical data computed from 10 minutes interval measurements.

eventId: data

Resources:

Temperature min

Minimal temperature measured since the last message

Details:

  • name: temperature_min
  • category: temperature
  • unit: unit.celsius
  • type: number
  • min value: -40
  • max value: 85
  • error value: 90

Temperature max

Maximal temperature measured since last message

Details:

  • name: temperature_max
  • category: temperature
  • unit: unit.celsius
  • type: number
  • min value: -40
  • max value: 85
  • error value: 90

Temperature avg

Average temperature since last message

Details:

  • name: temperature_avg
  • category: temperature
  • unit: unit.celsius
  • type: number
  • min value: -40
  • max value: 85
  • error value: 90

Humidity min

Minimal humidity measured since last message

Details:

  • name: humidity_min
  • category: humidity
  • unit: unit.percentage
  • type: number
  • min value: 10
  • max value: 95
  • error value: 100

Humidity max

Maximal humidity measured since last message

Details:

  • name: humidity_max
  • category: humidity
  • unit: unit.percentage
  • type: number
  • min value: 10
  • max value: 95
  • error value: 100

Humidity avg

Average humidity since last message

Details:

  • name: humidity_avg
  • category: humidity
  • unit: unit.percentage
  • type: number
  • min value: 10
  • max value: 95
  • error value: 100

Message: Device startup

Occurrence: When sensor device starts

eventId: device-start

Resources:

Temperature instant

Instantaneous temperature

Details:

  • name: temperature_instant
  • category: temperature
  • unit: unit.celsius
  • type: number
  • min value: -40
  • max value: 85
  • error value: 90

Humidity instant

Instantaneous humidity

Details:

  • name: humidity_instant
  • category: humidity
  • unit: unit.percentage
  • type: number
  • min value: 10
  • max value: 95
  • error value: 100