START Temperature v1

START Temperature collects over long distance and in real time temperature measurement.

Details:

  • device: START_Temperature
  • version: 1
  • deviceType: START_Temperature_v1

Message: Device startup

Occurrence: when devices starts for the first time or reboots

eventId: startup

Resources:

Temperature internal

Instantaneous internal temperature on sensor startup.

Details:

  • name: temperature_internal
  • category: temperature
  • unit: unit.celsius
  • type: number
  • min value: -40
  • max value: 85
  • error value: 86

Temperature channel 1

Instantaneous temperature of channel 1 on sensor startup.

Details:

  • name: temperature_channel_1
  • category: temperature
  • unit: unit.celsius
  • type: number
  • min value: -40
  • max value: 150
  • error value: 160

Temperature channel 2

Instantaneous temperature of channel 2 on sensor startup.

Details:

  • name: temperature_channel_2
  • category: temperature
  • unit: unit.celsius
  • type: number
  • min value: -40
  • max value: 150
  • error value: 160

Message: Trame de mesure 1

Only sent if there is only one channel on the device.

Occurrence: 10 minutes

Sends an average of the temperature (measured every minute) since the last message.

eventId: data_1

Resources:

Temperature internal min

Minimum sensor's internal temperature since last message.

Details:

  • name: temperature_internal_min
  • category: temperature
  • unit: unit.celsius
  • type: number
  • min value: -40
  • max value: 85
  • error value: 86

Temperature internal max

Maximum sensor's internal temperature since last message.

Details:

  • name: temperature_internal_max
  • category: temperature
  • unit: unit.celsius
  • type: number
  • min value: -40
  • max value: 85
  • error value: 86

Temperature internal avg

Average sensor's internal temperature since last message.

Details:

  • name: temperature_internal_avg
  • category: temperature
  • unit: unit.celsius
  • type: number
  • min value: -40
  • max value: 85
  • error value: 86

Temperature channel 1 min

Minimum channel 1 temperature measured since last message.

Details:

  • name: temperature_channel_1_min
  • category: temperature
  • unit: unit.celsius
  • type: number
  • min value: -40
  • max value: 150
  • error value: 160

Temperature channel 1 max

Maximum channel 1 temperature measured since last message.

Details:

  • name: temperature_channel_1_max
  • category: temperature
  • unit: unit.celsius
  • type: number
  • min value: -40
  • max value: 150
  • error value: 160

Temperature channel 1 avg

Average channel 1 temperature measured since last message.

Details:

  • name: temperature_channel_1_avg
  • category: temperature
  • unit: unit.celsius
  • type: number
  • min value: -40
  • max value: 150
  • error value: 160

Message: Trame de mesure 2

Only sent if there is two channel on the device.

Occurrence: 10 minutes

Sends an average of the temperature (measured every minute) since the last message.

eventId: data_2

Resources:

Temperature internal min

Minimum sensor's internal temperature since last message.

Details:

  • name: temperature_internal_min
  • category: temperature
  • unit: unit.celsius
  • type: number
  • min value: -40
  • max value: 85
  • error value: 86

Temperature internal max

Maximum sensor's internal temperature since last message.

Details:

  • name: temperature_internal_max
  • category: temperature
  • unit: unit.celsius
  • type: number
  • min value: -40
  • max value: 85
  • error value: 86

Temperature internal avg

Average sensor's internal temperature since last message.

Details:

  • name: temperature_internal_avg
  • category: temperature
  • unit: unit.celsius
  • type: number
  • min value: -40
  • max value: 85
  • error value: 86

Temperature channel 1 min

Minimum channel 1 temperature measured since last message.

Details:

  • name: temperature_channel_1_min
  • category: temperature
  • unit: unit.celsius
  • type: number
  • min value: -40
  • max value: 150
  • error value: 160

Temperature channel 1 max

Maximum channel 1 temperature measured since last message.

Details:

  • name: temperature_channel_1_max
  • category: temperature
  • unit: unit.celsius
  • type: number
  • min value: -40
  • max value: 150
  • error value: 160

Temperature channel 1 avg

Average channel 1 temperature measured since last message.

Details:

  • name: temperature_channel_1_avg
  • category: temperature
  • unit: unit.celsius
  • type: number
  • min value: -40
  • max value: 150
  • error value: 160

Temperature channel 2 min

Minimum channel 2 temperature measured since last message.

Details:

  • name: temperature_channel_2_min
  • category: temperature
  • unit: unit.celsius
  • type: number
  • min value: -40
  • max value: 150
  • error value: 160

Temperature channel 2 max

Maximum channel 2 temperature measured since last message.

Details:

  • name: temperature_channel_2_max
  • category: temperature
  • unit: unit.celsius
  • type: number
  • min value: -40
  • max value: 150
  • error value: 160

Temperature channel 2 avg

Average channel 2 temperature measured since last message.

Details:

  • name: temperature_channel_2_avg
  • category: temperature
  • unit: unit.celsius
  • type: number
  • min value: -40
  • max value: 150
  • error value: 160